Skip to content
PolyurethanePrimer

PPS01

PPS01 Fire-retardant white PU primer

Two-pack white polyurethane primer with fire-retardant additives for timber structures indoors. Fast drying, high solids (71 %), sands easily. When heated, the fire-retardant components break down and release a non-combustible gas that starves the fire of oxygen and slows flame spread. As the PPS01 primer + PPL01 enamel system it rates Group I fire-retardant efficiency to GOST R 53292-2009 (cl. 6.1). No official t-color.ru page - data from t-colormarket.ru and the Technocolor catalogues.

  • fire protection / improved fire resistance of interior timber structures
  • primer under the white fire-retardant enamel PPL01 (pigmented system, Group I)
  • public interiors needing certified fire protection: wall panelling, doors, cladding, stairs

Mix calculator

g
Hardener50.0 %

PC20: 50.0 % — fixed by the datasheet

When: standard hardener (dealer and catalogue list PC20 only)

Thinner25.0 %

When: universal, normal-evaporation thinner - the default

Ratio 100 : 50.0 : 25.0

ComponentWeigh out
PPS01part A286 g
PC20Hardener143 g
S50Thinner71.4 g
Total500 g

Covers roughly 3.33 m² at 150 g/m².

Working times: Use within 3 h · dry in 8 h (at 20 °C)

Ask about PPS01

Answers are based on the PPS01 data and the products it mixes with.

Questions are answered by our own AI server. Questions and answers are stored to improve the assistant and prevent abuse. Privacy policy

Mixing matrix

  • PC20Hardener
    % by weight: 50 %dealer% by volume: 60 %dealer

    standard hardener (dealer and catalogue list PC20 only)

    Fixed ratio - 50 % by weight, weigh it. By volume it's 60 %. Stir the base thoroughly first: the filler settles.

  • PC60Hardener
    % by weight: 50 %catalog% by volume: ≈ 60 %recommended

    allowed alternative per the fire-retardant leaflet - prefer PC20, as the dealer specifies

    PC60 is non-yellowing; under white enamel that doesn't matter for a primer. The fire certification was most likely run on PC20 - confirm with Technocolor before swapping.

  • S50Thinner
    % by weight: 20–30 (typ. 25) %dealer% by volume: 30–40 %dealer

    universal, normal-evaporation thinner - the default

    20 % for verticals and maximum build; 30 % if the gun spits on a 1.5-1.7 mm tip or it won't level on flats.

  • S80Thinner
    % by weight: 20–30 %recommended

    hot shop (above ~25 °C), large panels

    Not from Technocolor documentation. More dust pick-up and sag risk on verticals.

Percentages are per 100 parts of component A.

Characteristics

Solids
71 ± 1 %dealer
Viscosity
23 ± 1 sdealer
Pot life
3–4 hdealer
Drying · Touch-dry
30 mindealer
Drying · Fully dry
8 hdealer
Drying · Before sanding
≈ 8 h (overnight safest) hrecommended
Drying · Conditions
20 °C
Fire retardancy
Group I fire-retardant efficiency, GOST R 53292-2009 cl. 6.1dealer
Properties
fast drying; high solids; sands easilydealer
Density
≈ 1.2-1.3 g/ml (part A) g/mlrecommended
Thixotropy
probably not strongly thixotropic; heavy-bodiedrecommended

Colours

  • PPS01 · white

Application

HVLP

Nozzle
1.8–2 mmrecommended
Pressure · air
2–2.5 barrecommended
Spray viscosity
20–26 s DIN4recommended
Consumption
150 g/m²dealer
Wet film
≈ 130-140 µmrecommended
Coats
1 coat at 150 g/m² (the certified system figure) coatsrecommended
Flash-off
10–20 minrecommended
Recoat
enamel (PPL01) after full dry 8 h and sandingrecommended
Sanding between coats
280–320 grit Precommended

Spray, 150 g/m². 1.8-2.0 mm tip; a 1.5 mm won't atomise it well - if that's all you have, thin to 30 % S50 and accept less build per pass. 15-20 cm, 50 % overlap. Stir the base thoroughly before mixing.

Conventional spray

Nozzle
1.8–2 mmrecommended
Pressure · air
3–4 barrecommended
Consumption
150 g/m²dealer
Transfer efficiency
up to 40 %official

Technocolor just says 'spray'. Transfer only up to 40 % (methods page) - mix more than you think.

Airmix (air-assisted airless)

Nozzle
0.28–0.33 mmrecommended
Pressure · fluid
50–90 barrecommended
Pressure · air
1–2 barofficial
Consumption
150 g/m²dealer

Not listed by Technocolor, but a normal way to shoot primer on panels and doors in production.

Airless

Nozzle
0.33–0.38 mmrecommended
Pressure · fluid
120–180 barrecommended
Consumption
150 g/m²dealer
Transfer efficiency
up to 90 %official

Not listed by Technocolor. High transfer, easy to hit 150 g/m² in one pass; watch for sags on verticals.

Brush

Why ru
Дилер и оба каталога указывают только распыление.

Not recommended: Technocolor specifies spray only; a brush won't lay an even 150 g/m², which the fire rating depends on. Touch-up only.

Process and compatibility

Substrate preparation
Wood/MDF at 8-12 % MC, sanded P150-P180 (solid) or P180-P220 (MDF), de-dusted. No oil, wax or old finish - the fire rating assumes application to bare wood.recommended
Goes over
bare wood (interior timber structures) / bare MDF / wood boards
Goes under
PPL01
Sanding
280–320 grit Precommended
Don'ts
  • don't eyeball the hardener - 50 % by weight
  • don't use the mix past 3-4 h
  • don't sand before full dry (8 h)
  • don't skimp - below 150 g/m² per layer the fire rating isn't guaranteed
  • don't topcoat with ordinary (non-fire-retardant) enamels if you need the certified system
  • not for exterior use - interiors only

Storage

Shelf life
≈ 12 months unopened monthsrecommended
Storage temperature
+5…+25 °C, sealed, away from heat/sparksrecommended

Used in finishing systems

    Mixed into

    PC20

    Sources

    Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” comes from industry best practices (hover to see the reasoning).

    Not covered by the sources
    • No official t-color.ru product page; no Technocolor TDS/SDS PDF found (web search budget exhausted this session; dealer search only returns the dealer page)
    • Density not published (derived ≈1.2-1.3 g/ml)
    • Volume % for PC60 option not published
    • Sanding/stack time, dust-free time not published (only touch 30 min, full 8 h)
    • Spray viscosity, nozzle and pressure not published (all derived)
    • Shelf life and storage temperature not published
    • Gloss of the primer not rated
    • Whether the fire certification covers PC60 hardener (leaflet allows PC20/PC60 for the system; dealer lists PC20 only)
    • Minimum dry-film thickness / number of coats required for the GOST R 53292 Group I rating beyond '150 g/m²'
    • Hardness, chemical resistance, elasticity values not published
    • Not used in any official finishing schedule (information/technology)

    Independent referenceThis site is not affiliated with Technocolor. I'm just a fan of their products and happy to see such a great company in Russia.

    © 2026 TechnoCalc Designed by John Mark DouganAboutPrivacy