Skip to content
PolyurethaneLacquerGloss: 20 ± 3 GU 60°

PTL01

PTL01 Fire-retardant polyurethane lacquer, 20 gloss

Two-pack fire-retardant polyurethane topcoat, 20 gloss (satin-matt). When heated, the fire-retardant components decompose and give off non-combustible gas that blocks oxygen and slows fire spread. Fast drying (including to packing), excellent flow-out, pleasant soft feel. Used as the topcoat over clear fire-retardant primer PTS01; together they form a Group II fire-protection system to GOST R 53292-2009 (cl. 6.1). Interior use only.

  • Protecting and improving fire resistance of timber structures indoors
  • Clear topcoat in the PTS01 + PTL01 fire-retardant system (Group II, GOST R 53292-2009)
  • Wall panelling, cladding, doors and furniture in public interiors where certified fire protection is required

Mix calculator

Workbench
g
Hardener50.0 %

PC25: 50.0 % — fixed by the datasheet

When: Standard hardener per the dealer card

Thinner25.0 %

When: Normal conditions, verticals

Ratio 100 : 50.0 : 25.0

ComponentWeigh out
PTL01part A286 g
PC25Hardener143 g
S50Thinner71.4 g
Total500 g

Covers roughly 3.33 m² at 150 g/m².

Working times: Use within 4 h · dry in 8 h (at 20 °C)

Ask about PTL01

Answers are based on the PTL01 data and the products it mixes with.

Questions are answered by our own AI server. Questions and answers are stored to improve the assistant and prevent abuse. Privacy policy

Mixing matrix

  • PC25Hardener
    % by weight: 50 %dealer% by volume: 50 %dealer

    Standard hardener per the dealer card

    Fixed ratio — do not tweak it; the fire rating is certified on this formulation.

  • PC20Hardener
    % by weight: 50 %catalog% by volume: 50 %recommended

    Catalogue and leaflet list PC20 as the hardener; dealer lists it as an alternative: more flexible film, slower drying

    Sources disagree: catalogue/leaflet say PC20, dealer says PC25 (PC20 as alternative). Both at 50 %.

  • PC60Hardener
    % by weight: 50 %recommended% by volume: 50 %recommended

    When non-yellowing matters (pale timber, whitewashed tones)

    Swap sourced from the dealer; percentage taken by analogy with PC25.

  • S50Thinner
    % by weight: 20–30 (typ. 25) %dealer% by volume: 20–30 (typ. 25) %dealer

    Normal conditions, verticals

    Catalogue and leaflet give the same 20–30 % (basis not stated). Dealer: 20–30 % both by weight and by volume. 'default 25' is the mid-point (derived).

  • S70 / S80Thinner
    % by weight: 20–30 (typ. 25) %recommended% by volume: 20–30 (typ. 25) %recommended

    Hot weather — for better flow-out (dealer); in practice above ~25 °C (workshop notes)

    S80 is slow: more dust pick-up and sag risk on verticals. Does not change cure time.

Percentages are per 100 parts of component A.

Characteristics

Solids
44 ± 1 %dealer
Viscosity
65 ± 5 sdealer
Gloss
20 ± 3 GU 60°dealer
Pot life
4 hdealer
Drying · Touch-dry
30 mindealer
Drying · Fully dry
8 hdealer
Drying · Before sanding
≥ 8 h (pack/stack after full dry; leave 24 h before heavy handling)recommended
Drying · Conditions
20 °C
Fire protection
II группа огнезащитной эффективности, ГОСТ Р 53292-2009 (п. 6.1) — in system with PTS01dealer
Lightfastness
Moderate with PC25/PC20; use PC60 when yellowing mattersrecommended
Chemical resistance
высокая физико-химическая стойкость (range claim)catalog
Elasticity
PC20 instead of PC25 increases flexibility (and slows drying)dealer
Thixotropy
norecommended

Application

HVLP

Consumption
150 g/m² per coatdealer
Coats
1 coat PTL01 over PTS01 at 150 g/m² each (a second PTL01 coat only if build is needed)recommended
Recoat
Over PTS01: after it has dried ≥ 4 h and been sanded (overnight is safer); PTL01 over PTL01: 4–8 h after sanding, or within 24 h without full cure lock-outrecommended
Sanding between coats
Sand PTS01 with P320–P400 before PTL01; denib PTL01 between coats with P400–P600. Don't polish the 20-gloss final coat.recommended

Manufacturer lists spraying only (dealer, catalogue) — no brush/roller. Lay it on at the full 150 g/m²: under-building the film costs you the fire rating.

Conventional spray

Consumption
150 g/m²dealer

Methods page: transfer efficiency up to ~40 %, so gun usage will be well above the 150 g/m² that lands on the part.

Airmix (air-assisted airless)

Consumption
150 g/m²dealer

Methods page: airmix fluid pressure 'up to 20 bar', atomising air 1–2 bar.

Airless

Consumption
150 g/m²dealer

Methods page: airless up to 200 bar, transfer up to 90 %, ideal for priming large flats. For the topcoat airmix usually gives a cleaner finish with less sag/orange peel.

Process and compatibility

Substrate preparation
Clean dry timber (8–12 % MC), sanded P150–P180, dust removed. No oils, waxes or silicone.recommended
Goes over
PTS01
Don'ts
  • Don't use outdoors — interior-only material (dealer, catalogue)
  • Don't change the 50 % hardener ratio — the fire rating is certified on the formulation
  • Don't skimp on film: under 150 g/m² the system may not reach Group II
  • Don't use the mix past its 4 h pot life
  • Don't polish the 20-gloss finish — you'll get shiny patches

Storage

Packaging
1 л, 5 л, 25 лdealer
Storage temperature
+5…+25 °C, sealed, away from heatrecommended

Safety: Flammable solvent-borne material (the wet lacquer burns — the fire rating applies to the cured film only); contains isocyanates once mixed. Spray in a booth, wear an A2P2 organic-vapour respirator (or air-fed), nitrile gloves and eye protection. Keep away from flames and sparks.

Used in finishing systems

    Mixed into

    PC20

    Sources

    Value tags: “official”, “dealer”, “catalog”, “schedule” are Technocolor data; “workshop” is from our own datasheets; “recommended” comes from industry best practices (hover to see the reasoning).

    Not covered by the sources
    • No official t-color.ru product page
    • No real TDS / SDS PDF found
    • Density not published
    • Shelf life not published
    • Hardness, abrasion and chemical-resistance numbers not published
    • Dust-free time not published (only touch 30 min)
    • Pot life with PC20/PC60 not published
    • Not in any official finishing schedule (information/technology)
    • All nozzle/pressure/viscosity application data are derived — no manufacturer spray settings exist
    • Fire-rating test certificate number not seen (leaflet says certificates are supplied on request)
    • Hardener % by volume for PC20/PC60 and thinner % by volume for S70/S80 not published (derived from PC25/S50 dealer ratios)
    • Catalogue/leaflet ratios (PC20 50 %, S50 20–30 %) do not state weight vs volume
    • Hardener solids not published — dry-film estimate is approximate
    • Official methods page airmix fluid pressure ('до 20 bar') is lower than the derived 40–80 bar working window

    Independent referenceThis site is not affiliated with Technocolor. I'm just a fan of their products and happy to see such a great company in Russia.